FID Elevator Inverter

FID Elevator Inverter

2.1 Naming rules


图片10.png


Fig 2-1 Naming rules


2.2 Nameplate

Nameplate of FID series inverter applicable to asynchronous motor:


图片11.png

Fig 2-2 Nameplate


2.3 Main models of FID series inverters

Table 2-1 Models

 

 

Inverter model

Power volume kVA

Input current A

Output current A

Applicable motor kW

3-phase 380V   Range:-15%~20%

FWI-FID3-2d2

4.0

5.8

5.1

2.2

FWI-FID3-3d7

5.9

10.5

9.0

3.7

FWI-FID3-5d5

8.9

14.6

13.0

5.5

FWI-FID3-7d5

11.0

20.5

18.0

7.5

FWI-FID3-011

17.0

29.0

27.0

11

FWI-FID3-015

21.0

36.0

33.0

15

FWI-FID3-018

24.0

41.0

39.0

18.5

FWI-FID3-022

30.0

49.5

48.0

22

FWI-FID3-030

40.0

62.0

60.0

30

FWI-FID3-037

57.0

77.0

75.0

37

FWI-FID3-045

69.0

93.0

91.0

45


2.4 Technical Specification

Table 2-2 Technical Specifications

Item

Specification

Basic specification

Carrier frequency

0.5k~16k(Hz) ; Carrier frequency can be adjusted

automatically according to the load characteristic.

Input frequency resolution

Data setting:0.01Hz   Analog setting:highest

frequency×0.1%

Output frequency accuracy

Data setting:highest frequency×±0.01% Analog setting:

highest frequency×±0.01%

Control mode

Split-ring vector control (SVC)/ Closed loop vector control

(VC)

Startup torque

0.5Hz/180%(SVC); 0Hz/200%(VC)

Speed control range

1:100 (SVC)

1:1000 (VC)

Speed accuracy

±0.5%(SVC)

±0.05%(VC)

Overload capability

150% rated current for 60 seconds; 180% rated current for 1 second.

Speed up and speed down curve

Straight line or S curve acceleration and deceleration way;4 group acceleration and deceleration time and S

curve settings;   various combinations

Testing and mending control

Can be appointed by any multi-stage speed

Multi-stage running

Realize at least 8 stage speed



Item

Specification


Automatic voltage regulation(AVR)

Keep output voltage permanent, when network voltage changes

Display and operation

LED display

Display setting frequency, output frequency, output voltage, output current and other parameters

Parameter copy

LCD operating panel makes a copy of parameters quickly

 

Protection function

Provide 40 kinds of protection such as electrify short circuit survey, in-out lack phase protection, over current

protection,   over   voltager   protection,   undervoltage

protection etc.

 

Key lock and function choosing

 

Set partial or complete lock of the keys; define function range of part of the keys to avoid misoperation

Special function

Electrify peripheral equipment safety self-examination

Implement electrify and do peripheral equipment detection like grounding, short circuit etc.

Blackout emeegency function

The realization of emergency project is easy and convenient

Over speed protection

Elevatoe over speed protection function built in; various operation choices

Judgment of speed deviation

Speed deviation testing function built in to find out potential risks in time

Forced speed changing function

Effectively avoid hoisting and resting of the elevator

Motor temperature testing

Judge the temperature of the motor in time and eliminate potential risks

Startup compensation

Two ways of startup torque compensation;analogue or

digit

QUICK key

Customers can define shortcut menu freely

Timing control

Convenient for timing

 

Input/output characteristi

Running order channel

Three channels:decided by operation panel, control

terminal, communication

 

 

Frequency source

Five frequency source:decided by digit, analogue voltage, analogue current, communication, multi-stage speed

 

 

 

Input terminal

10-path digit input terminal, 1 path of it can be used as high-speed pulse input, which is compatible to PNP or NPN

3-path analogue input terminal, 1 path of it can only be used as voltage input, another one can be used as voltage or current input.

 


Item

Specification


 

 

Output terminal

3-path digit output terminal

2-path relay output terminal

2-path analogue output terminal, 0/4~20mA or 0/2~

10V can be chosen,can realize the output of setting

frequency, output frequency and other physical quantities

Circumstance

Altitude

Lower than 1000 meters

 

Surrounding temperature

-10℃~+40℃(when within 40℃~50℃,derating is

required)

Humidity

Less than 95%RH,no condensation

Vibration

Less than 5.9 m/s²(0.6g)

Storage temperature

-20℃~+60℃


QQ截图20180404175048.png

Fig 2-6   FID series Inverter(2.2kW~15kW)figure and Installation sizes

QQ截图20180404175059.png 

Fig 2-7 FID series Inverter(18.5kW~45kW)figure and Installation sizes

 

2.5.2 FID series Installation sizes

Table 2-4 Installation sizes

 

Inverter model

A

mm

B

mm

H

mm

H1 mm

W

mm

D

mm

Size mm

Gross

weight kg

    FWI-FID3-2d2

113

172

186

/

125

164

φ5.0

1.1

FWI-FID3-3d7

 

148

 

236

 

248

 

/

 

160

 

183

 

φ5.0

 

2.5

FWI-FID3-5d5


 

Inverter model

A

mm

B

mm

H

mm

H1 mm

W

mm

D

mm

Size mm

Gross

weight kg

FWI-FID3-7d5

 

 

190

 

 

305

 

 

322

 

 

/

 

 

208

 

 

192

 

 

φ6

 

 

6.5

FWI-FID3-011

FWI-FID3-015

FWI-FID3-018

 

 

235

 

 

447

 

 

432

 

 

463

 

 

285

 

 

228

 

 

Φ8

 

 

20

FWI-FID3-022

FWI-FID3-030

FWI-FID3-037

 

260

 

580

 

549

 

600

 

385

 

265

 

Φ10

 

32

FWI-FID3-045

 

 

 QQ截图20180404175428.png

   Fig 3-3   Applicable to FID series inverter