• SY16C-Tier 3
  • SY16C-Tier 3
  • SY16C-Tier 3
  • SY16C-Tier 3
  • SY16C-Tier 3
  • SY16C-Tier 3
  • SY16C-Tier 3
  • SY16C-Tier 3

V5-BA VFD for Textile

Special purpose VFD for Textile

Special Purpose VFD V5−BA Series Inverter for Textile  

1.1 Product Model Description

The digits and letters in the inverter model field on the nameplate indicate such information as the inverter series, power supply class, power class and software/hardware versions.

V5-BA.png

1.2 Product Nameplate Description

V5-BA-1.png


1.3 Product Series

V5−BA−4T□□□

Power (kW) 

7.5
1115
18.5
2230
37455575
90
Motor Power (kW)7.5111518.522303745557590


Output

Voltage (V)

Three-phase 0 to rated input voltage

Rated current (A)

17
22
30
3744
56
72
91
110
142
176

Overload capacity

150%   1 minute, 180%   10 seconds, 200%   0.5 second, interval: 10 minutes (inverse time lag feature)



Input

Rated

voltage/frequency

Three-phase 380V/480V; 50Hz/60Hz

Allowable voltage

range

323V ~ 528V; Voltage imbalance 3%; allowable frequency fluctuation: ±5%

Rated current (A)19
26
33
41
48
62
79
100
121
156
194
Braking unit

Built-in as standard

Built-in as option

Protection class

IP20

Cooling mode

Forced air convection cooling


1.4 Technical Specifications of Product

Control features

Control mode

Vector control 1

Vector control 2

Startup torque

0.50Hz   180%

0.25Hz   180%

Speed adjustment range

1:100

1:200

Speed stabilization precision

± 0.5%

± 0.2%











Product functions

Key functions

Undervoltage adjustment, switching of AC operation grounding, protective grounding and DC operation grounding, rotation speed tracing, torque limitation, multi-speed operation (up to 23 speeds), auto-tuning, S curve acceleration/deceleration, slip compensation, PID regulation, drooping control, current limiting control, manual/auto torque increase, current limiting.


Frequency setting mode

Frequency can be set via operation panel, UP/DN terminal, or analog inputs of AI1 / AI2/A3, or terminal pulse DI, and can also be set through communication with host computer.

Frequency range

0.00 ~ 300.00Hz Note: In the control mode of vector control 1 0.0 ~

3000.0Hz, the range can be customized according to the customer demand

Startup frequency

0.00 ~ 60.00Hz

Acceleration/deceleration time

0.1 ~ 36000s

Powered braking capacity

Braking unit action voltage: 650 ~ 750V; Operating time: 0.0 ~ 100.0S;

DC braking capacity

DC braking initial frequency: 0.00 ~ 300.00Hz; DC braking current:   Variable torque: 0. 0 ~ 90.0% .DC braking time: 0.0 ~ 30.0s; there is no initial waiting time for the DC braking to realize quick braking

Magnetic flux braking function

Ongoing action and no action upon deceleration as option, no action upon deceleration at default














Unique functions

Multifunctional M key

The unique multifunctional key is used to set the frequently used operations: JOG, emergent stop, Running command issuing mode switch , menu switching

Multiple menu modes

Basic menu mode, fast menu mode.  Menu mode of Non-factory setting function codes, Menu mode of last changed 10 function codes


Parameter copy

The standard operation panel can realize the parameter upload, download and display the copy progress. User can select to forbid the overwriting of the uploaded parameters.

Displayed/hidden function code

The customer can select to display or hide the function codes by themselves.

Dual RS485 communication ports

Support Modbus protocol (RTU). The standard operation panel can realize the function of remote control box   with a maximum distance of 500m.

Operation panel

Button type operation panel, protection class: IP20 as standard, IP54 as

Shared DC bus

The full series can realize shared DC bus supply for several inverters.

Independent duct

The full series adopts independent duct design and supports the installation of heatsink outside the cabinet

Universal expansion interface

Universal expansion board equipped with CPU for supporting customers secondary development: physical interface SPI bus, software protocol Modbus


Expansion card

User’s secondary development card, injection molding machine interface card,  PG  feedback  card,  air  compressor  control  card,  communication adapter  card,  power  monitoring  card,  phase  sequence  detection  card,


Power-up auto-detection

Realizing the power-up auto-detection of internal and peripheral circuits, including motor grounding, abnormal +10V power supply output, abnormal analog input, and disconnection




Protection function

Power supply undervoltage, overcurrent protection, overvoltage protection, interference protection, abnormal comparison reference input, auto-tuning failure, module protection, heatsink overtemperature protection, inverter overload protection, motor overload protection, peripheral protection, abnormal current detection, output to ground short circuit, abnormal power failure during operation, abnormal input power, output phase failure, abnormal EEPROM, relay suction pull-on anomaly, temperature sensor taking sample anomaly, encoder disconnection, abnormal +10V power supply output, abnormal analog input, motor overtemperature (PTC), abnormal communication, abnormal version compatibility, abnormal copying, abnormal expansion card connection, terminal mutual exclusion detection failure, hardware overload protection

Efficiency

At rated power, 7.5KW to 45kW power class ≥95%;55kW to 90KW power class ≥98%




Environment



Operating site

The inverter shall be mounted vertically in the electric control cabinet with good ventilation. Horizontal or other installation modes are not allowed. The cooling medium is the air. The inverter shall be installed in the environment free from direct sunlight, dust, corrosive gas, combustible gas, oil mist, steam and drip.

Ambient temperature

-10  ~  +40ºC, derated at  40  ~  50ºC, the  rated  output current shall  be decreased by 1% for every temperature rise of 1ºC

Humidity

5 ~ 95%, no condensing

Altitude

0  ~  2000m,  derated  above  1000m,  the  rated  output  current  shall  be decreased by 1% for every rise of 100m

Vibration

3.5mm,2 ~ 9Hz;10 m/s2,9 ~ 200Hz;15 m/s2,200 ~ 500Hz

Storage temperature

−40 ~ +70℃



1.5 Product Component Name

V5-BA -02.png



1.6 Product Outline, Mounting Dimension, and Weight

V5-BA Size.png

 

V5−BA series Product outline, mounting dimension, and weight

Voltage class

Inverter model

Outline and mounting dimension (mm)

Approximate weight

(kg)

WHDW1H1D1W2

Mounting hole diameter

V5−BA−4T7.5

206303
153166
2519613686.5
V5−BA−4T11

V5−BA−4T15

236386
201
236318
10217089.5

V5−BA−4T18.5

V5−BA−4T22


345


483


238


295


410


130


220


8


18

V5−BA−4T30

V5−BA−4T37

V5−BA−4T45

400
610297
340520183
26010
30

V5−BA−4T55

V5−BA−4T75

470
639302
410
545183320
1040

V5−BA−4T90

V5−BA-57 series Product outline, mounting dimension, and weight

Voltage class

Inverter model

Outline and mounting dimension (mm)

Approximate weight

(kg)

WHDW1H1D1W2

Mounting hole diameter

V5−BA−4T7.5-57

206303
185166
2519613687.5
V5−BA−4T11-57

V5−BA−4T15-57


236


386


245


226


308


102


170


8


10.5

V5−BA−4T18.5-57

V5−BA−4T22-57


345


483


286


285


400


130


220


8


19

V5−BA−4T30-57

V5−BA−4T37-57

V5−BA−4T45-57

400
610343330520183
26010
31

V5−BA−4T55-57

V5−BA−4T75-57

470
639350
400
545183320
1041

V5−BA−4T90-57

1.7  Terminal Wiring

V5-BA-03.png