V5-BA VFD for Textile
Special Purpose VFD V5−BA Series Inverter for Textile
1.1 Product Model Description
The digits and letters in the inverter model field on the nameplate indicate such information as the inverter series, power supply class, power class and software/hardware versions.
1.2 Product Nameplate Description
1.3 Product Series
V5−BA−4T□□□
Power (kW) | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | |
Motor Power (kW) | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | |
Output | Voltage (V) | Three-phase 0 to rated input voltage | ||||||||||
Rated current (A) | 17 | 22 | 30 | 37 | 44 | 56 | 72 | 91 | 110 | 142 | 176 | |
Overload capacity | 150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature) | |||||||||||
Input | Rated voltage/frequency | Three-phase 380V/480V; 50Hz/60Hz | ||||||||||
Allowable voltage range | 323V ~ 528V; Voltage imbalance ≤3%; allowable frequency fluctuation: ±5% | |||||||||||
Rated current (A) | 19 | 26 | 33 | 41 | 48 | 62 | 79 | 100 | 121 | 156 | 194 | |
Braking unit | Built-in as standard | Built-in as option | ||||||||||
Protection class | IP20 | |||||||||||
Cooling mode | Forced air convection cooling |
1.4 Technical Specifications of Product
Control features | Control mode | Vector control 1 | Vector control 2 |
Startup torque | 0.50Hz 180% | 0.25Hz 180% | |
Speed adjustment range | 1:100 | 1:200 | |
Speed stabilization precision | ± 0.5% | ± 0.2% | |
Product functions | Key functions | Undervoltage adjustment, switching of AC operation grounding, protective grounding and DC operation grounding, rotation speed tracing, torque limitation, multi-speed operation (up to 23 speeds), auto-tuning, S curve acceleration/deceleration, slip compensation, PID regulation, drooping control, current limiting control, manual/auto torque increase, current limiting. | |
Frequency setting mode | Frequency can be set via operation panel, UP/DN terminal, or analog inputs of AI1 / AI2/A3, or terminal pulse DI, and can also be set through communication with host computer. | ||
Frequency range | 0.00 ~ 300.00Hz Note: In the control mode of vector control 1 0.0 ~ 3000.0Hz, the range can be customized according to the customer demand | ||
Startup frequency | 0.00 ~ 60.00Hz | ||
Acceleration/deceleration time | 0.1 ~ 36000s | ||
Powered braking capacity | Braking unit action voltage: 650 ~ 750V; Operating time: 0.0 ~ 100.0S; | ||
DC braking capacity | DC braking initial frequency: 0.00 ~ 300.00Hz; DC braking current: Variable torque: 0. 0 ~ 90.0% .DC braking time: 0.0 ~ 30.0s; there is no initial waiting time for the DC braking to realize quick braking | ||
Magnetic flux braking function | Ongoing action and no action upon deceleration as option, no action upon deceleration at default | ||
Unique functions | Multifunctional M key | The unique multifunctional key is used to set the frequently used operations: JOG, emergent stop, Running command issuing mode switch , menu switching | |
Multiple menu modes | Basic menu mode, fast menu mode. Menu mode of Non-factory setting function codes, Menu mode of last changed 10 function codes | ||
Parameter copy | The standard operation panel can realize the parameter upload, download and display the copy progress. User can select to forbid the overwriting of the uploaded parameters. | ||
Displayed/hidden function code | The customer can select to display or hide the function codes by themselves. | ||
Dual RS485 communication ports | Support Modbus protocol (RTU). The standard operation panel can realize the function of remote control box with a maximum distance of 500m. | ||
Operation panel | Button type operation panel, protection class: IP20 as standard, IP54 as | ||
Shared DC bus | The full series can realize shared DC bus supply for several inverters. | ||
Independent duct | The full series adopts independent duct design and supports the installation of heatsink outside the cabinet | ||
Universal expansion interface | Universal expansion board equipped with CPU for supporting customers secondary development: physical interface SPI bus, software protocol Modbus | ||
Expansion card | User’s secondary development card, injection molding machine interface card, PG feedback card, air compressor control card, communication adapter card, power monitoring card, phase sequence detection card, | ||
Power-up auto-detection | Realizing the power-up auto-detection of internal and peripheral circuits, including motor grounding, abnormal +10V power supply output, abnormal analog input, and disconnection | ||
Protection function | Power supply undervoltage, overcurrent protection, overvoltage protection, interference protection, abnormal comparison reference input, auto-tuning failure, module protection, heatsink overtemperature protection, inverter overload protection, motor overload protection, peripheral protection, abnormal current detection, output to ground short circuit, abnormal power failure during operation, abnormal input power, output phase failure, abnormal EEPROM, relay suction pull-on anomaly, temperature sensor taking sample anomaly, encoder disconnection, abnormal +10V power supply output, abnormal analog input, motor overtemperature (PTC), abnormal communication, abnormal version compatibility, abnormal copying, abnormal expansion card connection, terminal mutual exclusion detection failure, hardware overload protection | ||
Efficiency | At rated power, 7.5KW to 45kW power class ≥95%;55kW to 90KW power class ≥98% | ||
Environment | Operating site | The inverter shall be mounted vertically in the electric control cabinet with good ventilation. Horizontal or other installation modes are not allowed. The cooling medium is the air. The inverter shall be installed in the environment free from direct sunlight, dust, corrosive gas, combustible gas, oil mist, steam and drip. | |
Ambient temperature | -10 ~ +40ºC, derated at 40 ~ 50ºC, the rated output current shall be decreased by 1% for every temperature rise of 1ºC | ||
Humidity | 5 ~ 95%, no condensing | ||
Altitude | 0 ~ 2000m, derated above 1000m, the rated output current shall be decreased by 1% for every rise of 100m | ||
Vibration | 3.5mm,2 ~ 9Hz;10 m/s2,9 ~ 200Hz;15 m/s2,200 ~ 500Hz | ||
Storage temperature | −40 ~ +70℃ |
1.5 Product Component Name
1.6 Product Outline, Mounting Dimension, and Weight
V5−BA series Product outline, mounting dimension, and weight
Voltage class | Inverter model | Outline and mounting dimension (mm) | Approximate weight (kg) | |||||||
W | H | D | W1 | H1 | D1 | W2 | Mounting hole diameter | |||
V5−BA−4T7.5 | 206 | 303 | 153 | 166 | 251 | 96 | 136 | 8 | 6.5 | |
V5−BA−4T11 | ||||||||||
V5−BA−4T15 | 236 | 386 | 201 | 236 | 318 | 102 | 170 | 8 | 9.5 | |
V5−BA−4T18.5 | ||||||||||
V5−BA−4T22 | 345 | 483 | 238 | 295 | 410 | 130 | 220 | 8 | 18 | |
V5−BA−4T30 | ||||||||||
V5−BA−4T37 | ||||||||||
V5−BA−4T45 | 400 | 610 | 297 | 340 | 520 | 183 | 260 | 10 | 30 | |
V5−BA−4T55 | ||||||||||
V5−BA−4T75 | 470 | 639 | 302 | 410 | 545 | 183 | 320 | 10 | 40 | |
V5−BA−4T90 |
V5−BA-57 series Product outline, mounting dimension, and weight
Voltage class | Inverter model | Outline and mounting dimension (mm) | Approximate weight (kg) | |||||||
W | H | D | W1 | H1 | D1 | W2 | Mounting hole diameter | |||
V5−BA−4T7.5-57 | 206 | 303 | 185 | 166 | 251 | 96 | 136 | 8 | 7.5 | |
V5−BA−4T11-57 | ||||||||||
V5−BA−4T15-57 | 236 | 386 | 245 | 226 | 308 | 102 | 170 | 8 | 10.5 | |
V5−BA−4T18.5-57 | ||||||||||
V5−BA−4T22-57 | 345 | 483 | 286 | 285 | 400 | 130 | 220 | 8 | 19 | |
V5−BA−4T30-57 | ||||||||||
V5−BA−4T37-57 | ||||||||||
V5−BA−4T45-57 | 400 | 610 | 343 | 330 | 520 | 183 | 260 | 10 | 31 | |
V5−BA−4T55-57 | ||||||||||
V5−BA−4T75-57 | 470 | 639 | 350 | 400 | 545 | 183 | 320 | 10 | 41 | |
V5−BA−4T90-57 |
1.7 Terminal Wiring